Operating
light is necessary equipment for operating light, it main role is to light
the surgical field to optimally observe objects in the incision and body with
different depths and low contrast. Of course because that the surgeon’s head,
hands and instruments may cause shadow in surgical filed, the operating light
should be designed to minimize the shadow, and color can be minimized. In
addition, it must be able to continue working for a long time without
experiencing excessive heat, because overheating can make the surgeon
uncomfortable, it can also dry the tissue in the surgical field, which can be
detrimental to the patient's recovery. Mingtai
company glad to introduce operating light characteristics to you.
1. Lamp shell is ABS
material, integrated design with four handles around and streamlined ultra-thin
design, the thickness is not more than 18CM, obtain excellent effect of laminar
flow.
2. The main light use 112LEDS(main bulb)+336LEDS(spare
bulb) independent LED illuminant (lamp cup is one main and three spare
bulb structure), divided into multiple independent illuminant group, subsidiary
light use 56LEDS(main
bulb)+3168LEDS(spare bulb) LED illuminant (lamp cup is one main and three
spare bulb structure), divided into multiple independent illuminant group;
every lamp use double CPU control, every group of LED illuminant controlled by
special circuit chip, any group failure will not affect the normal use of
shadowless light.
3. Use international
advanced warm white LED as shadowless illuminant, environmental, lower energy
consumption LED bulb, bulb life: ≥60000 hours
4. The handle on the
central of lamp can be detachable, can take high temperature (≤ 134°C)
sterilization treatment, easily adjust, flexible fixed; Adopt balanced arm,
handy operate, and make sure the lamp stable during operation; has C-arm joint
control panel, has luminance prompt facility, provide environment lighting
models.
5. LED do not engender
infrared ray and ultraviolet radiation, it doesn’t have the temperature rise
and tissue damage caused by halogen shadowless light, can accelerate the wound
healing after surgery, and has no Radiation pollution.
6. Microcomputer
digital control, illumination can be adjustable; stepless adjustment, eight
segments continuous indicating, adjustment range: 10%-100%, backlight
illumination: ≥30 Lux; it offers illuminance memory function.
7. Adopt restrain
interference design of electromagnetic wave, avoid disturb with the other
equipment in operating room.
8. Use satlite oval
swing pipe design, can install 4 cantilever devices in complex operating room,
also can be reserved per hospital’s request, convenient to upgrade and provide
perfect solution for the increasing multi-media request of hospital.
9. Balanced system use
good quality arm module, more than 5 group
universal joints, every cantilever must has more than 3 joints which can be rotated
in 360°, equipped with fatigue correcting unit and fix position hand handle
device, easy to fix position after using for long time.
10. Equips with disc spring braking system, preventing drifting.
Rotation axis system with safety loading design. Focusing system device, use lightweight
central axis helix to drive four-point rod to adjust lamp angle, so that adjust
spot size.
11. Lamp panel radius of gyration: ≥182cm, the lamp can be pulled to
vertical floor, convenient to any angle illumination. Unify ABS operate handle
and mid-operation handle of Lamp rim convenient to operate. Product execute
international IEC standard.