For camera operating light, summer moisture should be noticed. When the conditions permit, ventilation holes shall be provided in the peripheral area of the operating light ceiling to ensure the cooling effect of the core components during surgery. Second, when the weather is wet, the internal camera system can be put into standby on regular basis. Because the internal transformers and other working parts emit heat during the standby process, the moisture inside the operating light can be effectively dissipated. For external camera operating light, generally it is equipped with control panel and LCD display, the outer side of these components has many small holes. The dust will enter the operating light through these holes, when the weather is wet, the condensation will condense with the dust, resulting in a partial leakage; therefore, equipment maintenance personnel can use a hair dryer regularly to sweep out the dust and moisture in the interior through these holes. And for humid environment, it should be avoided that installing operating light near wall or corner, because the humidity in this area is more serious. For operating light with a certain number of years, Mingtai professional maintenance personnel can be scheduled to visit and clean the internal dust.


2018年3月21日星期三

How to choose surgical light for simple operating room


How to choose surgical light for simple operating room, and better assist doctors with surgery? Mingtai company glad to recommends some suggestions for you.
1. Surgical light illumination should meet simple operating room requirement
Some simple operating room don’t have enough light condition, the surgical light illumination should be considered firstly. Generally single dome surgical light illumination can reach 160,000 Lux. If conditions permit, an optional auxiliary light source can also be added to maximized the shadowing rate.
2. Surgical light power should meet the power supply standard of simple operating room
When we export surgical light to other countries, the local rated voltage should be asked, the surgical light can not be used when the voltage too high or too low, and even burn out its internal components.
3. Whether the surgical light is portable, and can be moved in simple operating room easily
In some disaster-stricken areas, especially where natural disasters are more serious, the simple operation room itself is facing various risks, and it is possible to relocate at any time. In this case, general ceiling model surgical light is relatively bulky, and the installation and disassembly is not as convenient as the portable surgical light. It can be judged according to the actual situation when choose surgical light.
4. Whether the surgical light need camera system
Now with the popularization of medical digital camera technology, simple operating room can also install camera surgical light. When you choose it you just need to consider which kind you need: internal camera or external camera system. By camera system, the diagnosis or surgical procedure can be recorded when dealing with difficult surgery, and send it to expert who is far away from you for help.



2018年3月20日星期二

Electro operation table cleaning and disinfection


Generally medical staff can clean and disinfect electro operation table parts according to the brand manual. It should be noticed that some parts can be cleaned with wet cloth, while some parts have very strict requirement when clean it.
Soft and wet cloth can be used to clean electro operation table surface, once a day or once every two days, if necessary, scrub with a soft cloth soaked in a disinfectant containing a chlorine preparation, make sure that the used disinfectant cloth are gentle, it will be much better if the operation table has a certain degree of corrosion resistance. Disinfectant should be mainly used in clinical practice, soaking for 2 hours in a 0.5% peroxyacid solution can kill bacteria, fungi and viruses, its main disadvantage is that it is corrosive to metals; Soaking in 2% dialdehyde alkaline solution for 30 minutes can kill fungi, viruses, tuberculosis and spores, it is the highest level of disinfectant at present, its disadvantages are mild irritation to the skin and mucous membranes, odor, it can be resumed after certain volatilization time; Soaking for 30 minutes in 2% SS disinfectant and then immersing for 1 hour in 1:1 ratio with 2.4% of SS disinfectant can also effectively kill bacteria.
Electro sensor is the most important core component for operation table, similar to the CPU in computer, it can neither be rinsed with water nor soaked in disinfectant, so as not to damage its electrical properties. It is recommended to use 70% alcohol swab to wipe gently.
As the main parts of electro operation table, hydraulic pump, speed control valve and solenoid valve should also be gently wiped with a clean, soft and wet cloth, and should not be soaked with disinfectant, in order to avoid affecting the heating function and reduce the accuracy of its control. All mattresses, table board, leg board, etc., between the patient and the operating table should be thoroughly disinfected, especially the cleansing and disinfecting of the gynecological operation table, they must be operated strictly according to the standardization process.

2018年3月19日星期一

Camera operation lamp structure features


Camera operation lamp has below features:
1. Operation lamp camera system consists of operation lamp, camera, multimedia computer digital monitoring system and monitor
2. Internal camera operation lamp use imported professional camera arm system, camera is put in the central of operation lamp handle, much beautiful and flexible.
3. For external camera operation lamp, the camera is put in one independent professional camera arm, 360 degree adjustment, image is much better.
4. Adopting imported brand intelligent camera, high definition; Optical zoom, auto iris, auto white balance. The digital control host adopts H264 compression method with higher resolution. With single/multi-screen real-time preview, switching display; automatically store images, video playback, remote network transmission and other functions.


2018年3月15日星期四

Improve shadowless lamp lighting by adjusting photothermal ratio


In the past, the old shadowless lamp usually used more power, mainly because of its photothermal ratio. As the input power becomes larger, the instantaneous high heat causes the bulb absorbing a large amount of electric energy and generating heat. Therefore, improving the proportion of photothermal ratio, designing shadowless lamp that satisfies illumination and avoids excessive operating room temperature becomes a new topic for Mingtai company.
The photothermal ratio is the ratio of shadowless lamp luminous power and the wavelength of all electron spectra in the surgical illumination area. Shadowless lamp should have low photothermal ratio, it can effectively improve the visible light of the electromagnetic spectrum which will be used to illuminate the brightness of the surgical site. Therefore, the surgeon can perform surgery in a comfortable surgical environment, and the lesion tissue will not cause inflammation due to heat.
In contrast, the high photothermal ratio means that the energy emitted by the surgical lamp is used to highlight the surgical lighting area in the visible part of the electromagnetic spectrum. Therefore, the surgeon may feel hot during surgery, even if its illumination is sufficient.

2018年3月14日星期三

What should be noticed when choose medical pendant?



As gas/power supply and equipment bearing medical equipment, medical pendant and bridge pendant has the role of line number management and improving the degree of laminar flow purification, it can support clean and high utilization rate working space for medical staff, bringing much convenience for them.
Medical pendant has different appearance design and function according to different departs usage. Generally, it is divided into operating room medical pendant and ICU medical pendant. So how to choose medical pendant for the 2 departments?
1.      Surgery type
Generally, surgery will use anesthesia machine, so the operating room should equip with surgery medical pendant which can meet the surgery requirement and anesthesia medical pendant which can supply anesthesia gas source and load anesthesia machine. Surgery medical pendant and anesthesia medical pendant are good choice for this kind surgery, flexible rotated arm can meet different surgery position requirement, fast, noiseless height lifting device to meet the requirements of laminar flow purification.
Endoscopic surgery also need anesthesia machine, so endoscopic operating room should equip with endoscopic medical pendant which can supply carbon dioxide gas source and anesthesia medical pendant which can supply anesthesia gas source and load anesthesia machine. Endoscopic medical pendant has multi trays to meet the endoscopic surgery requirement of loading equipment, good quality gas and power supply terminal can guarantee surgery safety.
2.      Purification level
According to different purification level, operating room has different types: 100 level operating room, 1,000 level operating room and 10,000 level operating room, the area of their purification ceilings respectively are: 2.6×2.4, 2.6×1.8, 2.6×1.4. Medical pendant has different arm configuration and installation position according to different purification ceilings area. The best choice for 100 level operating room is double arm medical pendant to meet different position requirement; For 1,000 level and 10,000 level operating room, considering its loading and convenience, surgery medical pendant and endoscopic medical pendant can choose double arm, anesthesia medical pendant can choose single arm.
The mention of purification level is mainly due to the consideration of anesthesia machine placement, the higher the purification level, the better the laminar flow purification effect is. Therefore, anesthesia medical pendant should choose electric lifting as far as possible.


2018年3月13日星期二

The right way to adjust operating light damping nail


Generally, the joints of operating light arm system use damping nails to adjust the elasticity, after the operating light is installed or used for a period of time, it is necessary to readjust the damping nail when the light cannot be stably parked at a desired position or when the adjustment force is too large, make sure the light head and the articulated arms have the proper starting force and can stay in the desired position stably. It should be noticed that the damping nail should be adjusted by professionals, the starting force of each joint satisfies the factory inspection requirements after adjustment, and the light head can stably stay in different positions.
The right way to adjust operating light arm
The value of operating light balance arm has been adjusted before leaving the factory, don’t need to adjust it without special situation. Balance arm angle can be adjusted according to need, make sure that the balance arm will not touch ceiling or other structures when it is moved up and down after adjustment.
When you need to adjust force or angle, it should be done after the light head is installed, adjust the arm after it is in the pull-down horizontal position.
Warning: When you remove the light head, you need to press down on the balance arm to prevent the balance arm from rebounding, then slowly place the balance arm in the corresponding equilibrium position.


2018年3月12日星期一

Comparison between electric operating table and other operating table


Operating table is basic medical equipment for surgery, it can be divided into 3 kinds: light operating table, manual hydraulic operating table and electric operating table.
Light operating table generally is made of sheet steel or other materials, mainly consists of 2 parts: table frame and table board. Its structure is simple and light, suitable for general medical treatment, examination and other surgical operations. Can be folded or disassembled when not in use, easy to load and transport. It can be deployed in simple operating rooms, tents, surgical shelters, and houses, as well as other special occasions, such as portable medical multi-purpose beds for field and field treatment. Compared with traditional operating table, its main features are foldable, small in size, light in weight, and easy to carry.
The manual hydraulic operating table uses the cylinder as an actuator to control various actions. Its main working process is: When the cylinder valve is opened, the upper and lower chambers of the cylinder communicate, and the piston can be adjusted to the desired position at this time; After closing the cylinder valve, the upper and lower chambers of the cylinder are separated. At this time, the position of the piston can be maintained due to the gas pressure in the cylinder.
The electric operating table uses electro transmission. Wired remote or infrared remote control, with the foot control panel, easy to adjust patients’ position, magnetic calve can be equipped.

2018年3月11日星期日

LED surgery lamp illumination characteristics


Surgery lamp is necessary medical equipment for surgery to light the surgical field, it is required to observe those objects with different depth, size and contrast in incision and body cavity clearly. Because the doctor’s head, hands and instruments may cause interference shadows on surgical field during surgery, surgery lamp is required to eliminate those shadows, and minimize color distortion. At the same time, the surgery lam must also be able to continue working for a long time and maintain low temperature rising state.
Now the mainly surgery lamp light source has 4 kinds: incandescent lamps, halogen lamps, gas discharge lamps and LED lamps. LED light source with those characteristics of energy efficient, cold light source and long lifetime, greatly reduces the irradiation energy in the surgical area, its lifetime is 40 times compared with halogen bulb, energy consumption is about 0.7 times compared with traditional light sources. With the development of LED technology and the improvement of its application level, it is theoretically possible to design different surgery lamps according to different positions of the patient's surgery and doctor position. Therefore LED surgery lamps greatly enhance the level of medical lighting.



2018年3月8日星期四

Operating light type and selection


There are many operating light types and manufacturers, and its functions also are difference, it is difficult to classify them by the same standard. Therefore, we generally classify them in the following ways:
Function: it is generally divided into operating light and examination light. Operating light has big size and much more function. Examination light has small base, and most of them are mobile type.
Appearance: it is divided into single dome and double dome operating light. Now Mingtai company can produce those 2 kinds operating lights. The principle of spotlighting is different, but there is not much difference in the use of effects.
Installation: ceiling model operating light, wall mounted model operating light and mobile model operating light. Most operating room use ceiling model operating light, wall mounted operating light can save much space for other import medical device, mobile model is often used as emergency operating light. Generally examination light is mobile type.
There are also have other classification methods, it can be divided into single dome, double dome and multi head dome operating light from complexity; it can be divided into keypad control and control box control from control method, and whether it is equipped with camera system, etc. Anyway, hospital and operating room can select operating light according to their need.



2018年3月7日星期三

Current status of electric operating table


Electric operating table meets the needs of human anatomy and medical care, has the following characteristics:
1.      Ergonomic design, can effectively reduce medical staff labor intensity.
2.      Beautiful appearance, high surface finish, corrosion resistance, high mechanical strength. The body is made of stainless steel, aluminum alloy, cast iron and other advanced materials. The table board is made of high-strength acrylic board which is anti-fouling, acid and alkali-resistant, durable and good X-ray penetration. Mattress prevents bedsore and static electricity.
3.      Type continue to increase. Including built-in waist bridge, five-section column, C-arm catheter, etc., convenient and safe, full functioning, high control precision, long service life.
4.      Intelligent. Computer-controlled operating table have increased substantially in recent years. They are controlled by computer system and all postures are controlled by single keys.
5.      Often equipped with a variety of components, to expand its function, suitable for surgery, gynecology, psychology, urology, ophthalmology, plastic surgery, anorectal, ENT and other departments.



2018年3月6日星期二

Mingtai halogen surgery lamp bulb common fault repair


Mingtai ZF700 series surgery lamp main bulb and spare bulb can be automatically changed when one is failure, and the indicator on the controller will be lighted. And there are several reasons that the indicator light:
1.      Main bulb or spare bulb failure, one indicator light, another indicator not light, and the surgery lamp work normally.
Analysis and processing: generally it is caused because the main bulb or spare bulb failure, through the surgery lamp can work normally, the failure bulb should be changed in time, avoiding affect surgery when main bulb and spare bulb failure at the same time. Cut power, unscrew the three fixing screws, pull out the handle assembly, change the failure bulb, when inserting the handle assembly into the lamp head, pay attention to the position of the hole, tighten the three fixing screws, turn on the power, then the surgery lamp can work normally.
2.      Main bulb and spare bulb failure, but the indicator light, surgery lamp not light, changing main bulb and spare bulb is still not working.
Analysis and processing: under normal circumstances, changing bulb can be monitored immediately by monitoring circuit, so it is necessary to find the reasons why cannot monitor it. Remove the handle assembly and gradually troubleshooting those parts and found that the line at main and auxiliary lamp socket public end has been carbonized, after measured found that it is cut off, resulting in automatic monitoring circuit cannot detect the lamp, replace the lamp holder machine then surgery lamp work normally.



2018年3月5日星期一

Halogen operating light daily maintenance and management



1.      Checking halogen operating light bulb working condition
Method: put one white paper in working area, if there is arc shadow, then change the bulb.
Sterilized handle condition: 2 sound “click” when install it
Clean: wash the surface with a mildly alkaline solvent (soapy water); avoid using chlorine-containing lotions (injury metal) and alcohol lotions (injury plastic and paint).
2.      Monthly inspection
Mainly check whether the backup power system (battery) is normal. Method: turn off the 220V power to see whether the backup power is start working.
3.      Bulb lifetime
Average halogen bulb lifetime is 1,000 hours. For light holders, basically it can be changed once a year, the premise is to use the light specified by the manufacturer.
4.      Annual inspection
Maintenance four steps
(1)   Tight: power cord connector (control box input and output office), screws at each joint, brush
(2)   Adjust: rotation limit lamp, operating light voltage (23V AC + DC), brakes for all joints
(3)   Check: vertical and balance of the suspension arm, whether the screw fastening in each connecting part is normal, whether the brake is normal when the joints move, rotation limit, cooling effect, lamp holder lamp state
(4)   Test: sterilized handle installation, illumination, spot diameter


2018年3月1日星期四

Surgery lamp reflector


Mingtai Surgery lamp reflector includes a plurality of reflection rings sequentially stacked from bottom to top, the radius of the horizontal cross-section of each reflection ring decreases from bottom to top, each reflection ring is composed of a plurality of reflecting surfaces with six sides and is connected in turn 360 degrees in the horizontal direction around the centerline of the reflector. Each reflection surfaces of the reflection ring are the same, and each reflecting surface is connected with adjacent reflecting surface through a common overlapping edge. Therefore, any reflecting surface must be divided into two symmetrical halves by a longitudinal section containing the center line and passing through two opposite ends of the reflecting surface. In any two adjacent reflection rings, the two oblique edges at the lower end of any reflection surface of the previous reflection ring respectively coincide and have the same length with one oblique edge on the upper ends of two adjacent reflection surfaces of the next reflection ring. Such a beneficial effect is that the reflected light is more evenly distributed, reflection focusing better, not easy to cause visual fatigue, and improve the rigidity of the reflector, the reflector is not easy to deform.

The advantages of Mingtai electric operating table in clinical application

Mingtai company has produced electric operating bed for many years, as professional electro or table manufacturer, Mingtai all aspects o...