Multi-parameter monitor
is a precision instrument that monitoring human vital signs, used in internal
medicine, surgery, operating room, ICU ward, CCU ward, emergency room,
obstetrics and gynecology, orthopedics, pediatrics and other places, so also
known as multi-parameter vital signs monitor. Generally applicable to the
serious condition patients who need uninterrupted monitoring of heart rhythm,
frequency, body temperature, pulse, breathing, blood pressure and blood oxygen
saturation.
Shandong Mingtai Medical Equipment Group Co.,
Ltd monitor can reflect the patient's instantaneous electrophysiological
changes, monitor the patient's vital signs information, helping clinically
detect problems, deal with problems, to ensure the patients’ safety.
Precautions
for use:
1.
Check
the instrument before usage, to see whether the cable connection line,
electrode is not aging, damage phenomenon, if any it should be replaced in
advance.
2.
Operator
should read the equipment manual carefully to avoid damage to the equipment due
to improper operation.
3.
Do
not place the equipment in an environment with anesthetic and flammable and
explosive materials, to prevent accidents such as fire and explosion.
4.
Clean
body measurement part with medical alcohol, cleaning stratum corneum and
perspiration, so as to avoid bad contact between skin and instrument electrodes,
which will result in measurement problems.
5.
Make
sure that the equipment is working without any other electromagnetic
interference.
6.
Carefully
place the power cord and cable to avoid winding together.
7.
Pay
close attention to patients’ actual clinical situation of, set the alarm volume
and alarm limits according to the patient's situation.
8.
When
it is found that the battery leaks or spread bad smell, it should be checked immediately,
the best way is changing a new battery.
9.
If
protect ground and the system is unstable, use an internal power supply
immediately.
10.
The
used accessories should form a complete set with instrument, using other
accessories many damage the instrument, you should use the instrument according
to manufacturer’s requirement.
11.
When
disposable and sterile package damaged, please immediately replace the damaged
package, so as not to affect the accuracy of the monitoring results.
12.
Electromagnetic
compatibility test should be conducted before using, in order to avoid the radio
frequency radiation signal interference to other medical equipment.
13.
When
the patient connect multiple instruments at the same time, the sum of leakage
current cannot exceed the required allowable value, so as not to cause electric
shock damage to the human body.
14.
For
the storage requirement, stay away from the source of electromagnetic
interference, corrosive drugs, high temperature, humidity, keep the environment
clean, to avoid vibration.
15.
Disposable
devices cannot be used once again, so as not to cause unnecessary pollution
15-inch
color TFT display, high resolution: 1024 × 768 dpi;
Parab
board separation: electrocardiogram, NIBP, arterial oxygen saturation plate;
Real-time
S-T segment analysis, ARR analysis;
Arterial
oxygen saturation tone tone change and drug dose calculation;
Color
optional parameter waveform and character;
Long
display: standard, big font, trend Coexis OxyCRG dynamic;
Standby
mode for energy saving and pause monitoring;
7-lead
ECG waveform display;
Capture
dynamic waveforms;
Built-in
rechargeable lithium battery, battery capacity display, AC power;
Effective
resistance to interference defibrillators and high frequency knives;
SINNOR
F-6 arterial oxygen saturation technique, VS NELLCOR accuracy;
Network
capacity and TCP / IP network platform enable rich future upgrades, delay
shutdown function to maintain monitoring data restart monitoring;
Complete
and flexible installation of transport, inpatient surveillance solutions