Operating light is the most
import light in operating room, affecting surgery result. Now let’s talk about
the main points when you choose operating light.
Firstly, we
should to know how it works generally.
During surgery
preparation phase, nurse or surgeon will move the operating light to probably
surgery position. Then turn on it, generally surgeon will stand under the light
at the same time, adjusting light position until meeting surgeon’s requirement
When surgery
started, generally the operating light position will not change. But when the
surgery filed or incision depth changed, the light also should be changed,
surgeon or nurse can adjust it by handle.
Finally, after
long time surgery, nurse or surgeon move operating light out of surgery field,
remove disinfecting handle and disinfect it.
From above we
can see that the main operator is nurse and surgeon. Before and after surgery,
nurse should move the operating light for long distance. And for surgeon, no
matter surgeon doctor or assistant, they will stand under operating light for
long time, have very close relationship with operating light.
So how to choose
suitable operating light? I think we should consider into below 4 points:
1.
Safety
Safety will be
the most import factor for medical equipment. This safety not only means
product safety, but also means the safety for user.
We will not talk
much more about product safety, because now the operating light standards are
much perfect both at home and abroad, and some Chinese test standards are
higher than Europe standards. Most factories’ standards’ also is high, so the
product safety is very small problem.
But some
problems often happen which are caused by incorrect installation because of the
complex design, or caused by lack of training.
Such as 2 common
problems: some halogen operating light will flash, turn off or brightness
becomes darker, causing blurry surgery filed. Generally it is because you don’t
change the halogen light bulb in time, or you don’t install connector
correctly. Another problem is that the hanging arm can’t be fixed, it will
drift during surgery, it mainly caused by incorrect installed hanging arm.
We can see that
it will have great influence for surgeon when surgery filed blurry or spot
drift during surgery, maybe it will be failed, causing unimaginable
consequences. So we should always warn
ourselves and others safety awareness in the daily work.
2. Suitable lighting environment
Besides safety, another
important point is suitable lighting environment. For one surgery, surgery will
stare at the surgery filed 90% time, others also will see surgery filed most of
their time. Suitable lighting
environment can let medical staff “see clearly, look for a long time”
‘See clearly’ means the color is not
distorted, organs can be distinguished, without shadow.
During surgery, it
is a prerequisite for the color to remain constant for a long time. If the red
color become other colors when lighting it, it will cause surgeon’s misjudgment;
When incision is deep, organs and blood vessels will mixed, and the color is
similar, it is hard to distinguish; At the same time, when incision is deep, because
the medical instrument’s block, maybe shadow will be formed, blocking surgeon
sight.
“See clearly”, operating light can meet this
requirement by keeping constant CRI, adjusting color temperature and high
shadowless affect.
“Look for a long
time” means look comfortable and look for a long time. For surgeon,
soft and not blinking spot can reduce surgeon’s visual fatigue; besides,
surgeon stands under the operating light for a long time, if the temperature
rise on surgery head is high, surgeon will feel uncomfortable, and it also will
cause the surgery filed temperature rise, maybe body fluids loss, causing
dangerous.
But lighting
environment depends on light source, with the technology development, from
halogen operating light, Xenon light, to the newest LED operating light, light
source’s development also improve light environment.
3.
Operate convenient, flexible and accurate
Before or after
surgery, operating light should be moved in/out surgery filed quickly; during
surgery, it should be adjusted according to surgeon’s need, and it should
constant position for a long time during surgery, no drift
Generally,
operating light’s light head is bigger no matter weight or volume. So for operate convenient, flexible and
accurate, it has very strict design requirement for light head and hanging arm.
The light head should reduce the volume and weight as much as possible
while satisfying the appropriate lighting environment, the shape design also
needs to minimize the impact on the purified laminar flow; Hanging arm
components should move convenience, flexible and accurate positioning in the
premise of carrying light head safety, and taking less space.
Now basically
every brand light head is unique, hanging arm components use imported famous
brand to confirm it quality and functions. Such as Mingtai brand, it light head
has petal model, and it hanging arm is Germany Ondal arm.
4.
Others
Besides above 3
points, some factories have its own unique design, making operating light using
convenience and long time. Such as Mingtai LED bulb, it has 4
LED bulb in one LED cup, 1 main bulb + 3 auxiliary bulb, can offer much better
shaodwless environment. And the hanging arm equips with patented
disc spring braking system, can preventing drifting effectively.